f. Upon successful update, the following dialog boxes will appear. Do not restart the server
at this time.
CAUTION: Do not power off or power down the server until the firmware for all
components in this procedure have been updated.
12. Shutdown the OS.
13. Unplug all power cables from the server, and wait at least 30 seconds.
CAUTION: After flashing the System Programmable Logic Devices, the power must cycle for
the changes to take effect. All power cables must be unplugged for at least 30 seconds to
allow the components to lose their residual charge. Pressing the power button is not sufficient.
14. If installing new processors, install them now. Follow the instructions located in the Maintenance
and Service Guide, which can be located on the web at: http://www.hp.com/go/
proliant_servers-docs.
15. Connect the power cables to the server.
16. Power up the server (dc on).
17. Verify post by watching post codes through iLO IRC (bottom banner). This step is optional,
but recommended.
Procedure for Solaris and VMware
For Solaris and VMware use the “Flashing firmware using Offline Update Method” (page 3).