HP MicroServer Remote Access Card User Manual

65
Troubleshooting BMC
Heartbeat LED Indicator
The Heartbeat LED (CR1, which location is near the “Aspeed” chipset) is used to indicate whether the
BMC work normally or not. When BMC firmware works normally, it should blink with one second
interval. Otherwise, the BMC firmware should be in ill.
When encounter this failure, you should remove the server power and reboot the server (unplug the
server power cable, and then plug it again) to let BMC reboot. If the heartbeat LED still works
abnormally after server power on, you can attempt to flash the latest BMC firmware via the method
Update BMC Firmware under DOS mode
, Windows, Linux.
System Event Log Entries
Event Log Display Event Log explanation
EvtLogDisabled: Event Log sensor,
Log Area Reset/Cleared was
asserted
When clear SEL via Web UI “clear log” or using
IPMI command.
Sys Pwr Monitor: Power Unit sensor,
Power Off / Power Down was
asserted
When power off the server.
Sys Pwr Monitor: Power Unit sensor,
Power Off / Power Down was
deasserted
When power on the server.
SYS_FAN: Fan sensor, failure event
was asserted
When fan unplugged or failed.
SYS_FAN: Fan sensor, failure event
was deasserted
When fan recovers working normally from a
failure or unplugged condition.
CPU_THEMAL: Temperature sensor,
warning event was asserted
When CPU temperature upper warning
threshold going high
CPU_THEMAL: Temperature sensor,
warning event was deasserted
When CPU temperature return lower warning
threshold
CPU_THEMAL: Temperature sensor,
failure event was asserted
When CPU temperature upper failure threshold
going high
NB_THERMAL: Temperature sensor,
warning event was asserted
When North Bridge temperature upper warning
threshold going high
NB_THERMAL: Temperature sensor,
warning event was deasserted
When North Bridge temperature return lower
warning threshold
NB_THERMAL: Temperature sensor, When North Bridge temperature upper failure