HP MicroServer Remote Access Card User Manual

66
failure event was asserted threshold going high
AMBIENT_THERMAL: Temperature
sensor, warning event was asserted
When ambient temperature upper warning
threshold going high
AMBIENT_THERMAL: Temperature
sensor, warning event was
deasserted
When ambient temperature return lower
warning threshold
AMBIENT_THERMAL: Temperature
sensor, failure event was asserted
When ambient temperature upper failure
threshold going high
SEL Rate: Other FRU sensor,
Warning event was asserted
Non-critical for SEL rate: The SEL storage space
is 25% in remaining.
EvtLogDisabled: Event Log sensor,
SEL Almost Full was asserted
Warning for SEL space: The SEL storage space
is 20% in remaining.
SEL Rate: Other FRU sensor, failure
event was asserted
Critical for SEL rate: The SEL storage space is
10% in remaining.
EvtLogDisabled: Event Log sensor,
SEL Full was asserted
Out of space: EventLog could not be recorded
because of a lack of storage space
System Software event: Memory
sensor
Uncorrectable ECC/other uncorrectable memory
error
JVM Support
When you want to use the function vKVM or vMedia, please make sure that JVM is installed on
your client. Please see this
HP website for the download link.
Login Issues
Use the following information when attempting to resolve login issues:
Try the default login, which is located on the network settings tag.
If you forget your password, an administrator with the Administer User Accounts privilege can
reset it.
If an administrator forgets his username or her password, the administrator can use the IPMI
command method to get username and reset password. Please review “How to get username
and password when forgetting the BMC login user name and password”.
Check for standard problems, such as:
Is the password complying with password restrictions? For example, are there case sensitive
characters in the password?
Is an unsupported browser being used?
Firewall Issues
BMC communicates through several configurable TCP/IP ports. If these ports are blocked, the
administrator must configure the firewall to allow for communications on these ports. See the
Administration section of the BMC user interface to view or change port configurations.