ProLiant ML110 Generation 2 Cabling Matrix

This matrix
p
rovides information on cables re
q
uired to connect internal and external o
p
tions.
The ML110 G2 includes a single SCSI cable for the connection of the system hard drives. To use a second SCSI channel for tape backup, drive
duplexing, connection of the two-bay drive cage, or connection of external SCSI devices; a second SCSI cable is required.
Use this matrix to identify any additional cables that may be required.
Option
SCSI Connector
on the Option
Cable Type Included
with the Option Supported HBAs/Controllers Additional Cables Required
Internal Hard Drives
SATA non-hot-plug drive in
standard non-hot-plug drive cage
none
No SATA cable included with
the option
The non-hot-plug drive cage can be connected to one of the following:
Integrated SATA host controller (SATA Models)
6-Port SATA RAID Controller (355671-B21)
Follow the same HDD utility end user order to maintain
cable quantity
Ultra320 Non-Hot-Plug Hard
Drives in standard non-hot-plug
drive cage
LVD Wide 68 Pin
No SCSI cable included with
the option
The non-hot-plug drive cage can be connected to one of the following:
Slot-based Ultra320 SCSI Controller (SCSI Models)
HP Single-Channel SCSI RAID Controller (P/N 355671-B21)
64-Bit/133-MHz single-channel Ultra320 SCSI HBA G2
(P/N 374654-B21)
No additional cables required
Internal Optical Stora
g
e
DRV, CD,48X UDMA cable N/A No additional cables required
internal Tape and Optical Stora
g
e
Tape 24i LVD Narrow 50 pin
50-to-68 pin adapter and
HD68-HD68 cable
Slot-based Ultra320 SCSI Controller (SCSI models)
64-Bit/133-MHz single channel Ultra320 SCSI HBA G2
(P/N 374654-B21)
No additional cables required
Tape 40i LVD wide 68 pin HD 68- HD68
Slot-based Ultra320 SCSI Controller (SCSI models)
64-Bit/133-MHz single channel Ultra320 SCSI HBA G2
(P/N 374654-B21)
No additional cables required
Tape 72i LVD wide 68 pin HD 68- HD68
Slot-based Ultra320 SCSI Controller (SCSI models)
64-Bit/133-MHz single channel Ultra320 SCSI HBA G2
(P/N 374654-B21)
No additional cables required
Disk-to-Disk backup solution, USB
2.0
None USB cable N/A No additional cables required
DVD-ROM/CD-RW, 48X combo None 18-in UDMA cable N/A No additional cables required
DVD-ROM/CD-RW, 48X combo
refresh
None 18-in UDMA cable N/A No additional cables required
FDD 1.44 Additional cables required for CTO models only
USB Floppy Drive No additional cables required
USB 1.44-MB external diskette
drive
No additional cables required
256-MB HP Drive Key No additional cables required
v90 56-K PCI Modem US No additional cables required
Cards
Slot-based Ultra320 SCSI
Controller (SCSI Models)
LVD wide 68 pin N/A N/A No additional cables required
64-Bit/133-MHz Single Channel
Ultra320 SCSI HBA G2 (P/N
374654-B21)
LVD wide 68 pin
No SCSI cable included with
the option
N/A
Internal SCSI cable, 4 drops (P/N 166389-B21) /
Internal SCSI cable, 2 drops (P/N 273463-B21)
HP Single Channel SCSI RAID
Controller (P/N 355671-B21)
LVD wide 68 pin
No SCSI cable included with
the option
N/A
Internal SCSI cable, 4 drops (P/N 166389-B21) /
Internal SCSI cable, 2 drops (P/N 273463-B21)
Hewlett-Packard Company shall not be liable for technical or editorial errors or omissions contained herein. The information in this document is provided "as is" without warranty of any kind and is subject to change without
notice. The information contained herein is subject to change without notice. The only warranties for HP products and servcies are set forth in the express warranty statements accompanying such products and services. Nothing
herein should be technical or editorial errors or construed as constituting an additional warranty. HP shall not be liable for
technical or editorial errors or omissions contained herein.
HP ProLiant ML110 Generation 2 Cabling Matrix
NOTE: The information in this matrix lists whether or not additional cables need to be purchased with each controller-to-option configuration. For information on how to
cable an option, refer to the HP ProLiant ML110 Generation 2 Reference and Troubleshooting Guide and the device-specific documentation. For information on the
specific options supported by the server, refer to the server and device QuickSpecs.
© 2002, 2005 Hewlett-Packard Development Company, L.P.