HP ProLiant Storage Server User Guide (440584-005, June 2008)

Status2. Online/activity LED
(green)
1. Fault/UID LED
(amber/blue)
A predictive failure alert has been received for this
drive. Replace the drive as soon as possible.
Off
Amber, flashing regularly (1
Hz)
The drive is offline, a spare, or not configured as
part of an array.
OffOff
Systems Insight Display LEDs and internal health LED
combinations
When the internal health LED on the front panel illuminates either amber or red, the server is
experiencing a health event. Combinations of illuminated system LEDs and the internal health LED
indicate system status.
Table 18 Systems Insight Display LEDs and internal health LED combinations
StatusInternal health LED
color
Systems Insight
Display LED and
color
One or more of the following conditions may exist:
Processor in socket X has failed.
Processor X is not installed in the socket.
Processor X is unsupported.
ROM detects a failed processor during POST.
Red
Processor failure,
socket X (amber)
Processor in socket X is in a pre-failure condition.Amber
One or more of the following conditions may exist:
PPM in slot X has failed.
PPM is not installed in slot X, but the corresponding
processor is installed.
Red
PPM failure, slot X
(amber)
FBDIMM in slot X has failed.Red
FBDIMM failure, slot
X (amber)
FBDIMM in slot X is in a pre-failure condition.Amber
One or more FBDIMMs has failed. Test each bank of FBDIMMs
by removing all other FBDIMMs. Isolate the failed FBDIMM by
replacing each FBDIMM in a bank with a known working
FBDIMM.
Red
FBDIMM failure, all
slots in one bank
(amber)
One or more FBDIMMs has failed. Test each bank of FBDIMMs
by removing all other FBDIMMs. Isolate the failed FBDIMM by
replacing each FBDIMM in a bank with a known working
FBDIMM.
Red
FBDIMM failure, all
slots in all banks
(amber)
Bank X failed over to the online spare memory bank.Amber
Online spare
memory (amber)
Invalid online spare memory configuration.Red
Online spare
memory (flashing
amber)
Server components50