HP ProLiant Storage Server Release Notes (January 2006)

48
Issue: Quick Restore does not reconfigure a default RAID1 RAIDset on the operating system drives
Description This issue exists across all platforms using the SmartArray controllers as the
operating system drive controllers.
If there is no RAID configuration on the operating system drives when you boot
the server, the SmartArray controller configures a default RAID1 drive across the
drives if you do not cancel the operation. If this RAID1 volume is present, the
Quick Restore process does not erase it, and you will get an array error during
the Quick Restore process.
Workaround Reboot the NAS server. During restart, using the iLO management connection or
NAS console, access the SmartArray ROM utility (press F8) and remove the
RAID1 set on the first two disks. Exit the utility allowing the Quick Restore process
to continue.
Issue: Quick Restore pauses during the finalization setup if the 100 series Lights-out card is
installed
Description The ML110 G2 Quick Restore process pauses during the finalization step (after
the DVD has been removed from the DVD drive) due to the EMS ability of the
Lights-out card.
Workaround Connect a keyboard, monitor, and mouse. Reply to the on-screen popup box.