5U Tower G6 Server Redundant Power Supply Enablement Option Installation Instructions
5U Tower G6 Server
Redundant Power Supply
Enablement Option
Installation Instructions
Legal notices
© Copyright 2009, 2012 Hewlett-Packard Development Company, L.P.
The information contained herein is subject to change without notice. The
only warranties for HP products and services are set forth in the express
warranty statements accompanying such products and services. Nothing
herein should be construed as constituting an additional warranty. HP shall
not be liable for technical or editorial errors or omissions contained herein.
Overview
This document contains instructions for installing the optional
Redundant Power Supply (RPS) enablement kit into a 5U tower server
chassis.
For more information on preparing the server for installation, see the
documentation referenced on the HP server product CD.
Kit contents
• RPS enablement kit
• Mounting screws (8)
• This document
Important safety information
Read the installation instructions completely before beginning the
installation procedure. For more information, see the Important
Safety Information document on the HP Server product CD.
CAUTION: Electrostatic discharge (ESD) can damage
electronic components. Be sure you are properly
grounded (earthed) before beginning an installation
procedure..
Installation guidelines
This installation must be performed by qualified personnel who are
knowledgeable of the procedures, precautions, and hazards
associated with equipment containing hazardous energy circuits.
Figure 1 Chassis layout
Item Description
1 Power supply unit
2 System board
3 Air baffle
Installing the RPS enablement kit
1. Back up the server data.
2. Shut down the operating system.
3. Power down the server.
4. Disconnect the power cord from the existing power supply unit.
5. If necessary, unlock the front bezel.
6. Loosen the access panel thumbscrews, and then remove the
panel.
7. Slightly pull up the air baffle release tabs, and then lift the air
baffle away from the chassis.
Figure 2 Removing the air baffle
8. Place the server on the side with the open side up.
9. Disconnect all power cables of the existing power supply from
the system board and the mass storage devices.
10. Remove the mounting screws that secure the existing power
supply to the chassis.
Figure 3 Removing the mounting screws
11. Slightly lift up the power supply, and then push toward the front
of the chassis until it clears the support ledge.
12. Tilt the power supply towards processor socket, and then
carefully remove the power supply from the chassis.
Part Number: 501526-002
Published: April 2012
Edition: 2