HP ProLiant ML310 G3 Storage Server Administration Guide (WSS R2 version, March 2006)

2. If you intend to congure a remote server, conrm that the ACU Execution Mode is set to remote
service.
3. Op en the browser, either locally (on the host) or on the remote server.
4. Enter the following text into the browser address eld (where servername isthenameorIPaddressof
the host):
http://servername:2301
The login screen for the System Management homepage opens.
5. Log in. The System Management homepage opens.
6. Click Array Conguration Utility on the left side of the window. The ACU opens and identies the
controllers that are connected to the system. This process could take a minute or two.
Some ACU guidelines to consider:
Do not modify Array A off of the Smart Array controller, because it contains the storage server
operating system.
Spanning more than 14 disks with a RAID 5 volume is not recommended.
Designate spares for RAID sets to provide greater protection against failures.
RAI D sets cannot span controllers.
A single array can contain multiple logical drives of varying RAID settings.
Extending and expanding arrays and logical drives is supported.
RAID migration is not supported.
The HP Array Conguration Utility User Guide is available for download at h
ttp://
h200002.ww w2.hp.com/bc/docs/support/SupportManual/c00294139/c00294139.pdf.
HP Storage M anager
The HP Sto
rage Manager supports the SATA R AID controller and SATA hard disk drives installed
on the storage server.
NOTE:
Not all SATA -based storage servers use hardware RAID with the HP Storage Manager.
54
File server management