HP ProLiant Support Pack 9.10 User Guide

The following table shows what updates occur if no switches are currently installed.
Gen8 serversG7 and earlier serversCommand
AMSSNMPno switches
AMSN/A/use_ams
SNMPSNMP/use_snmp
WBEMWBEM/use_wmi
AMS and SNMPSNMP/use_ams /use_snmp
AMS and WBEMWBEM/use_ams /use_wmi
WBEM and SNMPWBEM and SNMP/use_wmi /use_snmp
AMS, SNMP and WBEMWBEM and SNMP/use_ams /use_wmi /use_snmp
The following table shows what updates occur if SNMP switches are currently installed.
Gen8 serversG7 and earlier serversCommand
SNMPSNMPno switches
SNMP and AMSSNMP/use_ams
SNMPSNMP/use_snmp
WBEM and SNMPWBEM and SNMP/use_wmi
AMS and SNMPSNMP/use_ams /use_snmp
AMS, SNMP, and WBEMWBEM and SNMP/use_ams /use_wmi
WBEM and SNMPWBEM and SNMP/use_wmi /use_snmp
AMS, SNMP, and WBEMWBEM and SNMP/use_ams /use_wmi /use_snmp
The following table shows what updates occur if WBEM switches are currently installed.
Gen8 serversG7 and earlier serversCommand
WBEMWBEMno switches
WBEM and AMSWBEM/use_ams
WBEM and SNMPWBEM and SNMP/use_snmp
WBEMWBEM/use_wmi
AMS, SNMP, and WBEMWBEM and SNMP/use_ams /use_snmp
WBEM and AMSWBEM/use_ams /use_wmi
WBEM and SNMPWBEM and SNMP/use_wmi /use_snmp
AMS, SNMP, and WBEMWBEM and SNMP/use_ams /use_wmi /use_snmp
The following table shows what updates occur if AMS switches are currently installed.
Gen8 serversG7 and earlier serversCommand
AMSN/Ano switches
AMSN/A/use_ams
18 Advanced topics