Resetting System Configuration Settings
It may be necessary at some time to clear and reset system configuration
settings. When the system configuration switch position 6 is set to the on
position, the system is prepared to erase all system configuration settings from
both CMOS and NVRAM:
CAUTION: Clearing nonvolatile RAM (NVRAM) deletes your system
configuration. Refer to Chapter 5, Server Configuration and Utilities, for
instructions on configuring your server.
1. Power down the server.
2. Set the system configuration switch position 2 to the on position.
3. Power up the server.
All configuration settings are now erased and all system operations halt.
4. Power down the server.
5. Reset the position 2 switch to the default off position.
6. Power up the server.
7. Reset all system configuration settings by pressing the F9 key to run the
ROM Based Setup Utility (RBSU).
See Chapter 5, Server Configuration and Utilities, or the Compaq
ROM Based Setup Utility User Guide, for more information on RBSU.