Redundant ROM Settings
IMPORTANT: Switching ROM images can also be done through RBSU. Use the following
procedures when RBSU is inaccessible. For information on accessing redundant ROM
options through RBSU, as well as disaster recovery procedures, see Chapter 5, “Server
Configuration and Utilities.”
To switch from the current ROM to the backup ROM, perform the following
steps:
1. Power down the server.
2. Set the system configuration switch positions 1, 4, 5, and 6 to the on
position.
3. Power up the server. The ROM will beep and halt when the ROM
images have been swapped.
4. Power down the server and reset all system configuration switch
positions to the default off position.
5. Power up the server.
If both the current and previous versions of the ROM are corrupted, see
section “Disaster Recovery” in Chapter 5, “Server Configuration and