Compaq ProLiant ML330 Generation 2 Server Setup and Installation Guide

Specifications F-3
Compaq Confidential – Need to Know Required
Writer: Jennifer Hayward Project: Compaq ProLiant ML330 Generation 2 Server Setup and Installation Guide Comments:
Part Number: 234833-001 File Name: m-appf Specifications.doc Last Saved On: 5/23/01 11:47 AM
Minimum Hardware Configuration
Make sure that your server meets the requirements for minimum hardware
configuration. During the troubleshooting process, it may be necessary to
reduce your system to its minimum configuration, reinstalling options one at a
time to determine the cause of failure.
Table F-2
Minimum Hardware Configuration
Component Minimum Specifications
Processors A processor must be installed in processor socket 1.
Server Feature
Board
The Server Feature Board must be installed in expansion slot 6.
Fans A system fan must be installed and connected to the system board.
Memory At least one slot must be populated with a PC133-MHz ECC Registered
SDRAM DIMM.
Note: The maximum memory configuration is 4 x 1-GB memory modules.
Also refer to the Compaq ProLiant ML330 Generation 2 Server Maintenance
and Service Guide at the Compaq website:
http://www.compaq.com/support