Compaq ProLiant ML330 Generation 2 Server Setup and Installation Guide

Hardware Options Installation 3-35
Compaq Confidential Need to Know Required
Writer: Jennifer Hayward Project: Compaq ProLiant ML330 Generation 2 Server Setup and Installation Guide Comments:
Part Number: 234833-001 File Name: d-ch3 Hardware Options Installation.doc Last Saved On: 5/23/01 3:48 PM
Replacing the Server Feature Board Battery
When replacing the battery on the Server Feature Board, use a CR2032
three-volt lithium coin cell battery. To replace the Server Feature Board
battery:
1. Follow the steps in Removing the Access Panel at the beginning of
the chapter.
2. Remove the Server Feature Board from expansion slot 6. See Installing
an Expansion Board earlier in this chapter.
3. Release the battery by pressing outward on the battery holder latch, and
then lift the battery away from the holder.
4. Slide the replacement battery into the proper position with the positive
(+) side up.
Figure 3-31. Replacing the Server Feature Board battery
5. Replace the Server Feature Board in expansion slot 6.
See Installing an Expansion Board earlier in this chapter for detailed
instructions.
6. Replace the access panel, and then connect cables to the server.
7. Run RBSU to reconfigure your system by pressing the F9 key when
prompted during server startup. See Chapter 5, Server Configuration
and Utilities, or the Compaq ROM Based Setup Utility User Guide, for
more information on RBSU.