1. Follow the steps in Removing the Access Panel at the beginning of
this chapter.
2. Locate the battery on the system board. See Figure 3-26 for the location
of the battery.
NOTE: If you have expansion boards installed, it may be necessary to remove them in
order to gain access to the battery.
3. Slide the battery out of the holder . Lift the battery away from the
holder
.
1
2
Figure 3-26. Removing the battery from the system board
4. Slide the replacement battery into the proper position with the positive
(+) side up.
IMPORTANT: Positive polarity should be positioned up.
5. Reconfigure your system by running BIOS Setup utility (F10) for the
ProLiant ML330 server or RBSU (F9) for the ProLiant ML330e server.
See Chapter 5 for more information on these setup utilities.