HP ProLiant ML350e Gen8 v2 Server Maintenance and Service Guide
Removal and replacement procedures 27
WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the
internal system components to cool before touching them.
CAUTION: For proper cooling do not operate the server without the access panel, baffles,
expansion slot covers, or blanks installed.
1. Power down the server (on page 25).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Unlock the front bezel (on page 26).
4. Place the server on its side.
5. Remove the access panel:
a. Loosen the access panel thumbscrews.
b. Slide the access panel back.
c. Lift the access panel away from the chassis.
To replace the component, reverse the removal procedure.
PCI air baffle
To remove the component:
1. Power down the server (on page 25).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Unlock the front bezel (on page 26).
4. Place the server on its side.
5. Remove the access panel ("Access panel" on page 26).