Removal and replacement procedures 39
7.
Remove any PCI cards installed in PCI slots 3, 4, 5, and 6 ("Full-length expansion board" on page 41).
8. Disconnect the capacitor pack cable from the module.
9. Remove the FBWC module from the cache module connector on the system board.
To replace the component, reverse the removal procedure.
FBWC capacitor pack
CAUTION: The cache module connector does not use the industry-standard DDR3 mini-DIMMs.
Do not use the controller with cache modules designed for other controller models, because the
controller can malfunction and you can lose data. Also, do not transfer this cache module to an
unsupported controller model, because you can lose data.
To remove the component:
1. Power down the server (on page 25).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Unlock the front bezel (on page 26).
4. Place the server on its side.
5. Remove the access panel ("Access panel" on page 26).
CAUTION: In systems that use external data storage, be sure that the server is the first unit to be
powered down and the last to be powered back up. Taking this precaution ensures that the system
does not erroneously mark the drives as failed when the server is powered up.
6. If installed, remove the PCI air baffle ("PCI air baffle" on page 27).
7. Disconnect the capacitor pack cable from the cache module.
8. Remove the capacitor pack from the holder: