HP ProLiant Gen8 Troubleshooting Guide Volume I: Troubleshooting

Software problems 67
ROM problems
Remote ROM flash problems
Command-line syntax error
If the correct command-line syntax is not used, an error message describing the incorrect syntax is displayed
and the program exits. Correct the syntax, and then restart the process.
Access denied on target computer
If you specify a networked target computer for which you do not have administrative privileges, an error
message is displayed describing the problem, and then the program exits. Obtain administrative privileges
for the target computer, and then restart the process. Be sure the remote registry service is running on a
Windows®-based system.
Invalid or incorrect command-line parameters
If incorrect parameters are passed into command-line options, an error message describing the invalid or
incorrect parameter is displayed and the program exits (Example: Invalid source path for system
configuration or ROMPaq files). Correct the invalid parameter, and then restart the process.
Network connection fails on remote communication
Because network connectivity cannot be guaranteed, it is possible for the administrative client to become
disconnected from the target server during the ROM flash preparation. If any remote connectivity procedure
fails during the ROM flash online preparation, the ROM flash does not occur for the target system. An error
message describing the broken connection displays and the program exits. Attempt to ascertain and correct
the cause of connection failure, and then restart the process.
Failure occurs during ROM flash
The flash cannot be interrupted during this process, or the ROM image is corrupted and the server does not
start. The most likely reason for failure is a loss of power to the system during the flash process. Initiate
ROMPaq disaster recovery procedures.
Target system is not supported
If the target system is not listed in the supported servers list, an error message appears and the program exits.
Only supported systems can be upgraded using the Remote ROM Flash utility. To determine if the server is
supported, see the HP website (http://www.hp.com/go/hpsc).
System requests recovery method during a firmware update
When updating the firmware on a BitLocker-encrypted server, always disable BitLocker before updating the
firmware. If BitLocker is not disabled, the system requests the recovery method selected when BitLocker was
configured. Failure to provide the correct recovery password or passwords results in loss of access to all