HP ProLiant ML350p Gen8 Server Maintenance and Service Guide

Removal and replacement procedures 50
SFF drive backplane
To remove the component:
1. Do one of the following:
o For tower models, open and remove the bezel ("Remove the tower bezel" on page 27).
o For rack models, if installed, remove the security bezel (on page 27).
2. Power down the server (on page 26).
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. For tower models, do the following:
a. Place the server on a flat, level surface with the access panel facing up.
b. Remove the access panel ("Access panel" on page 29).
5. For rack models, do the following:
a. Extend the server from the rack (on page 28).
b. Remove the access panel ("Access panel" on page 29).
c. Release thumbscrews and remove the rack bezel.
6. Disconnect all cables from the drive backplane.
7. Using a T-15 screwdriver, remove the screws that secure the SFF drive cage to the server.