Configuring Arrays on HP Smart Array Controllers Reference Guide

HP Array Configuration Utility 88
Error code Error message Comment or clarification
successfully.
2053
Too many coinciding expansion, migration,
or extension operations
The new configuration requires more
transformations than are possible at one time. For
example, you cannot expand a logical volume and
transform its RAID level at the same time.
2056
Controller does not support license keys The controller does not support license key entry or
deletion.
2059
Invalid license key The entered license key is not a valid license key.
2064
Controller does not support SSP The controller does not support SSP functions.
2817
Invalid Action The requested actions are invalid, for example,
combining
-reset
with capture mode.
2818
Invalid Method The method must be either Custom or Auto.
2819
Invalid Controller An invalid controller value was specified.
2821
No controllers detected No controllers were detected. This error applies to
Input mode only.
2823
Invalid Rebuild Priority The specified rebuild priority is not supported.
2824
Invalid Expand Priority The specified expand priority is not supported. This
error also occurs if the controller does not allow
expansion, and therefore does not support expand
priority.
2825
Invalid Array The array ID is invalid.
2826
Array not specified The Array command is missing from the script file.
Some commands were found that require an Array
to be specified.
2827
New Array ID does not match the next
available Array ID.
The array ID in the script file does not match the
array ID of the next available array. For example, if
the configuration has an Array A and the input file
specifies Array C (without Array B), then the script
generates this error.
2828
New Array ID already exists
The array ID specified in the script file (in Configure
mode) already exists in the configuration. Configure
mode can only create new arrays.
2829
Cannot create Array The controller will not allow a new array to be
created, either because the controller has no
unassigned physical drives attached or because the
maximum number of arrays or logical drives has
been reached already.
2830
Cannot expand Array The Array could not be expanded, either because
the controller does not support expansion, or the
current configuration does not allow expansion to
occur on the array.
2831
Cannot change Array Spare The spare state of the array could not be changed.
This error can occur when you attempt to add or
drop a spare and the current configuration does not
allow a spare state change for the array.
2832
Invalid physical drive A specified physical drive is not a valid physical
drive, or it cannot be placed in the array.
2833
Invalid Spare A specified spare is not a valid spare drive, or it
cannot be placed in the array as a spare.
2834
Invalid logical drive The logical drive ID is not valid.