HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

HP Smart Array errors 108
QUEUE_FULL_ON_ZERO - Drive indicates that its queue is full when we have no
requests outstanding to the drive.
SMART_ERROR_REPORTED - Drive has reported a predictive-failure error when
controller is configured to automatically fail [instead of reporting imminent
failure of] drives that report this error.
PHY_RESET_FAILED - Phy reset request failed.
FR_CHKBLK_FAILED_WRITE - Drive failed write command while checking for media
errors.
FR_ATI_TEST_FAILED_WRITE - Drive failed write command while checking for
errors.
OFFLINE_ERASE - Drive is offline due to a Secure Erase operation.
OFFLINE_TOO_SMALL - Drive is offline because it’s a replacement drive that
is too small.
OFFLINE_DRIVE_TYPE_MIX - Drive is offline because it is not the correct type
for this array [SATA vs SAS].
OFFLINE_ERASE_COMPLETE - Drive is offline because a Secure Erase operation
has completed on it but it hasn’t been replaced yet.
Message Id: 24586
Severity: Informational
Log message: The <drive type> physical drive located in bay <bay number> is now
online. This drive can be found in box <box number> which is connected to port
<port number> of the array controller <controller name / slot information>.
Message Id: 24587
Severity: Warning
Log message: The <drive type> physical drive located in bay <bay number> is in a
SMART trip state that indicates the drive has reached 0 percent usage left.
Indicates that the drive has a SMART wear error and is approaching the maximum
usage limit for writes (wear out). The drive should be replaced as soon as
possible. This drive can be found in box <box number> which is connected to port
<port number> of the array controller <controller name / slot information>.
Message Id: 24588
Severity: Warning
Log message: Sensor number <sensor number> has reported that the internal
temperature has exceeded the preset limit. This sensor is located in box <box
number> which is connected to port <port number> of array controller <controller
name / slot information>. The array controller may attempt to shut down power
to the attached box and/or spin down the installed disk drive(s).
Message Id: 24589
Severity: Warning
Log message: Sensor number <sensor number> has reported that the internal
temperature is nearing the preset temperature limit. This sensor is located in
box <box number> which is connected to port <port number> of array controller
<controller name / slot information>. The array controller may enact
precautionary measures to prevent data loss should the temperature reach the
operating limit.