HP Smart Array errors 109
Message Id: 24590
Severity: Informational
Log message: Sensor number <sensor number> has reported that a previously existing
temperature condition has been corrected. This sensor is located in box <box
number> which is connected to port <port number> of array controller <controller
name / slot information>. All of the temperature sensors in the attached box are
now reporting acceptable temperature levels.
Message Id: 24591
Severity: Warning
Log message: Redundant power supply number <power supply number> has reported a
fault. This power supply is located in box <box number> which is connected to
port <port number> of array controller <controller name / slot information>.
Message Id: 24592
Severity: Informational
Log message: Redundant power supply number <power supply number> is no longer sensed
as being in a failed state. Some possible reasons that would cause this state
change to occur include:
1. The previously failed power supply has returned to an operational state.
2. The previously failed power supply was removed from the chassis.
The power supply state change occurred in box <box number> which is connected
to port <port number> of array controller <controller name / slot information>.
Message Id: 24593
Severity: Informational
Log message: Array controller <controller name / slot information> has reported that
more physical devices were detected than the controller is currently capable of
supporting. Some physical drives will not be accessible.
Message Id: 24594
Severity: Warning
Log message: Redundant path number <path number> for the <drive type> physical drive
located in bay <bay number> has either failed or been removed. The drive can be
found in box <box number> which is attached to port <port number> of array
controller <controller name / slot information>.
Message Id: 24595
Severity: Error
Log message: A drive failure notification has been received for the <drive type>
physical drive located in bay <bay number>. This drive can be found in box <box
number> which is connected to port <port number> of the array controller
<controller name / slot information>. The failure reason received from the HP
Smart Array firmware is: <firmware error code>.
<firmware error code> values:
TOO_SMALL_IN_LOAD_CONFIG - Replacement drive is too small for configured
volume(s).