HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

HP Smart Array errors 114
EJECTED
ERASING
UNKNOWN
Message identifiers 24600-24624
Message Id: 24600
Severity: Error
Log message: Logical drive <logical drive number> of array controller <controller
name / slot information> has encountered a status change from:
Status: <previous status>
to
Status: <current status>
<previous status> and <current status> values:
OK
FAILED
NOT CONFIGURED
INTERIM RECOVERY MODE
READY FOR RECOVERY
RECOVERING
WRONG PHYSICAL DRIVE REPLACED
PHYSICAL DRIVE NOT PROPERLY CONNECTED
HARDWARE IS OVERHEATING
HARDWARE HAS OVERHEATED
EXPANDING
NOT YET AVAILABLE
QUEUED FOR EXPANSION
DISABLED DUE TO SCSI ID CONFLICT
EJECTED
ERASING
UNKNOWN
Message Id: 24601
Severity: Informational
Log message: Logical drive <logical drive number> configured on array controller
<controller name / slot information> is in a failed state but has had one or more
drive replacements and is now ready to change to a status of "OK". However, this
status change will not occur until the logical drive is re-enabled. Please
re-enable the logical drive either via the HP Array Configuration Utility or by
rebooting the system.