HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

HP Smart Array errors 154
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> is indicating that a previously existing temperature condition
on the controller from sensor <sensor number> has been corrected. All of the
temperature sensors are now reporting acceptable temperature levels.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24797
Severity: Informational
Log message: The <drive type> physical drive located in bay <bay number> has passed
a pre-defined usage threshold. It currently has <days or percent> <days of /
percentage> usage remaining. Indicates that the drive is approaching the maximum
usage limit for writes (wear out). This drive can be found in box <box number>
which is connected to port <port number> of the array controller <controller name
/ slot information>.
Message Id: 24798
Severity: Informational
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> is reporting that the <drive type> physical drive located in
bay <bay number> has passed a pre-defined usage threshold.
It currently has <days or percent> <days of / percentage> usage remaining.
Indicates that the drive is approaching the maximum usage limit for writes (wear
out).
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id: 24799
Severity: Warning
Log message: The <drive type> physical drive located in bay <bay number> could not
be authenticated as a genuine HP hard drive. This drive's status LEDs will not
be controlled. This drive can be found in box <box number> which is connected
to port <port number> of the array controller <controller name / slot
information>.
Message identifiers 24800-24808
Message Id: 24800
Severity: Warning
Log message: The external Smart Array controller located in the MSA chassis labeled
as <chassis label> is reporting that the%3physical drive located in bay <bay
number> could nobe authenticated as a genuine HP hard drive. This drive's status
LEDs will not be controlled.
The external Smart Array controller is attached to the host side Smart Array
controller <controller name / slot information>.
Message Id 24801
Severity: Informational
Log message: Array controller <controller name / slot information> has reported that
its cache is missing. This is an unsupported configuration.