HP Onboard Administrator errors 203
Event messages include the device affected, the device name, and the date and time of the event. Some
examples of event messages are:
The enclosure is in a degraded state.
Blade X has experienced a failure.
The temperature on Blade X has exceeded the failed threshold.
Fan X has experienced a failure.
The power supplies are no longer redundant.
Power supply X is in a degraded state.
The enclosure temperature has exceeded the degraded threshold.
Command line event notifications
When the SET DISPLAY EVENTS option is turned on, the terminal interface displays error, warning, and status
messages, depending on the behavior of the enclosure and components.
The syntax for these messages are:
<error>Description of error
<warning>Description of warning
<status>Description of status
The following table lists causes of the error, warning, or status events that appear.
Event Cause
Bay Event
A bay was assigned or unassigned from a
group.
Blade Inserted
A blade was inserted into the enclosure.
Blade Thermal Status
Changed
The thermal status of a blade changed.
Blade Removed
A blade was removed from the enclosure.
Blade Port Map Info
The port mapping information of a blade was
updated.
Enclosure Status Change
A change in status has occurred because of a
change in the state of one or more hardware
components or server readings.
Enclosure Name Change
The name of the enclosure was changed.
Fan Status Change
The status of a fan has changed.
Fan Inserted
A fan has been inserted.
Fan Removed
A fan has been removed.
Interconnect Inserted
An interconnect module was inserted into the
enclosure.
Interconnect Thermal Status
Changed
The thermal status of an interconnect module
changed.
Interconnect Removed
An interconnect module was removed from the
enclosure.
Interconnect Power Reset
The power of an interconnect module was reset.
Interconnect Port Map Info
The port mapping information of an