HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

HP iLO errors 232
Event log display Event log explanation
Power on request received by: Type
A power request was received as one of the following
types:
Power Button
Wake On LAN
Automatic Power On
Virtual NMI selected by: User
Displays when an authorized user selects the Virtual NMI
button.
Virtual Serial Port session started by: User
Displays when a Virtual Serial Port session is started.
Virtual Serial Port session stopped by: User
Displays when a Virtual Serial Port session is ended.
Virtual Serial Port session login failure from: User
Displays when a login failure occurs.
Embedded media manager failed initialization
Displays if iLO cannot start the embedded subsystem. Reset
iLO and try again. The embedded media subsystem
includes the internal SD-Card slot and the AHS store.
Blob store file system is inconsistent. It will be
reinitialized on the next iLO reset and unavailable
until then.
Displays when an internal management data store is
corrupt. Some management functions may be unavailable
until iLO is reset to reinitialize.
Media controller exception
Displays when one of several possible exceptions is
generated by the Internal SD-Card and AHS Media
controller. The exception should self correct.
Unable to fetch valid embedded media manager
firmware image
Displays when iLO cannot find the Media controller in the
system firmware. There is a ROM issue or a system failure
causing the error.
Self test error attempting to test the media controller
Displays when iLO is unable to communicate with the
Media controller. This is a system failure that can result in
loss of SD-Card slot and AHS functionality.
Could not start embedded media controller
Displays when the Media controller initialization failed.
Could not attach to embedded media controller
Displays when the Media controller initialization failed.
Restarted
Displays when iLO is reset and successfully restarted the
Media controller.
Failed restart
Displays when iLO tried and failed to reset the Media
controller. A retry of the reset may succeed.
Firmware upgrade via online flash component
failed.
Displays when the iLO Firmware could not be upgraded
from the Online ROM Flash components.
RIBCL messages
The following table lists the error messages displayed when using the RIBCL XML scripting language.
Status number Error message
0x0000
No error.
0x0001
Syntax error.
0x0002
This user is not logged in.
0x0003
Login name is too long.
0x0004
Password is too short.
0x0005
Password is too long.
0x0006
User table is full. No room for new user.
0x0007
Cannot add user. The login/ user name already exists.