HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

Microsoft Windows Event ID and SNMP traps 289
Symptom: External Array Physical Drive Status Change. This trap indicates that the agent has detected a
change in the status of a physical drive. The variable cpaFcaPhyDrvStatus indicates the current physical drive
status.
User Action: If the physical drive status is threshExceeded(4), predictiveFailure(5) or failed(6), replace the
drive.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSsChassisName
cpqSsChassisTime
cpqFcaPhyDrvBusNumber
cpqFcaPhyDrvBay
cpqFcaPhyDrvStatus
cpqFcaPhyDrvModel
cpqFcaPhyDrvSerialNum
cpqFcaPhyDrvFWRev
cpqFcaPhyDrvFailureCode
Supporting SNMP Trap Description: “Status is now [cpqFcaPhyDrvStatus] for a physical drive on bus
[cpqFcaPhyDrvBusNumber], bay [cpqFcaPhyDrvBay].”
NT Event ID: 1147 (Hex)0xc435047b (cpqstmsg.dll)
Log Severity: Error (3)
Event Title: External Array Spare Drive Status Change.
Log Message: The spare drive in port %5, bay %6 on array “%4” has a new status of %7.
SNMP Trap: cpqFcaSpareStatusChange - 16002 in CPQFCA.MIB
Symptom: External Array Spare Drive Status Change. This trap indicates that the agent has detected a
change in the status of an External Channel Array spare drive. The variable cpqFcaSpareStatus indicates the
current spare drive status. The variable cpqFcaSpareBusNumber indicates the SCSI bus number associated
with this drive.
User Action: If the spare drive status is failed, replace the drive.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSsChassisName
cpqSsChassisTime
cpqFcaSpareBusNumber
cpqFcaSpareBay
cpqFcaSpareStatus