HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

Microsoft Windows Event ID and SNMP traps 293
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSsChassisName
cpqSsChassisTime
cpqSsPowerSupplyBay
cpqSsPowerSupplyStatus
cpqSsPowerSupplySerialNumber
cpqSsPowerSupplyBoardRevision
cpqSsPowerSupplyFirmwareRevision
Supporting SNMP Trap Description: “Storage system power supply status changed to
[cpqSsPowerSupplyStatus].”
NT Event ID: 1154 (Hex)0x84350482 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Power Supply UPS Status Change.
Log Message: The UPS attached to storage system “%4” power supply bay %5 has a new status of %7.
SNMP Trap: cpqSsExPowerSupplyUpsStatusChange - 8018 in CPQSTSYS.MIB
Symptom: Storage system power supply UPS status change. The agent has detected a change status of a UPS
attached to a storage system power supply. The variable cpqSsPowerSupplyUpsStatus indicates the current
status.
User Action: If the UPS status is powerFailed(4) or batteryLow(5), restore power to the UPS.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSsChassisName
cpqSsChassisTime
cpqSsPowerSupplyBay
cpqSsPowerSupplyUpsStatus
Supporting SNMP Trap Description: “Storage system power supply UPS status changed to
[cpqSsPowerSupplyUpsStatus].”
NT Event ID: 1155 (Hex)0x84350483 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Temperature Sensor Status Change.
Log Message: Storage system “%4” temperature sensor at location %5 has a new status of %6 and a current
temperature value of %7 celsius.
SNMP Trap: cpqSsExTempSensorStatusChange - 8019 in CPQSTSYS.MIB