HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

Microsoft Windows Event ID and SNMP traps 305
Supporting SNMP Trap Description: “Status is now [cpqIdeLogicalDriveStatus] for the IDE logical drive.”
NT Event ID: 1188 (Hex)0x843504a4 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Fan Status Change.
Log Message: An enclosure attached to port %5 of storage system “%4” has a new fan status of %7. The
enclosure model is “%6”.
SNMP Trap: cpqSsExBackplaneFanStatusChange - 8022 in CPQSTSYS.MIB
Symptom: Storage System Fan Status Change. The agent has detected a change in the fan status of a storage
system. The variable cpqSsBackplaneFanStatus indicates the current fan status.
User Action: If the fan status is degraded or failed, replace any failed fans.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSsChassisName
cpqSsChassisTime
cpqSsBackplaneIndex
cpqSsBackplaneVendor
cpqSsBackplaneModel
cpqSsBackplaneSerialNumber
cpqSsBackplaneFanStatus
Supporting SNMP Trap Description: “Storage system fan status changed to [cpqSsBackplaneFanStatus].”
NT Event ID: 1189 (Hex)0x843504a5 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Temperature Status Change.
Log Message: An enclosure attached to port %5 of storage system “%4” has a new temperature status of %7.
The enclosure model is “%6”.
SNMP Trap: cpqSsExBackplaneTempStatusChange - 8023 in CPQSTSYS.MIB
Symptom: Storage System Temperature Status Change. The agent has detected a change in the status of the
temperature in a storage system. The variable cpqSsBackplaneTempStatus indicates the current status.
User Action: If the temperature status is degraded or failed, shut down the storage system as soon as
possible. Be sure that the storage system environment is being cooled properly and that no components are
overheated.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSsChassisName
cpqSsChassisTime