HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

Microsoft Windows Event ID and SNMP traps 307
sysName
cpqHoTrapFlags
cpqTapeLibraryCntlrIndex
cpqTapeLibraryBusIndex
cpqTapeLibraryScsiIdIndex
cpqTapeLibraryLunIndex
cpqTapeLibraryName
cpqTapeLibraryFwRev
cpqTapeLibrarySerialNumber
cpqTapeLibraryState
Supporting SNMP Trap Description: “Status is now [cpqTapeLibraryState].”
NT Event ID: 1192 (Hex)0x843504a8 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: SCSI Tape Drive Status Change.
Log Message: The tape drive with SCSI target %6 connected to SCSI bus %5 of the controller in slot %4 has
a new status of %2.
SNMP Trap: cpqTape5PhyDrvStatusChange - 5019 in CPQSCSI.MIB
Symptom: Tape Drive Status Change. The Storage Agent has detected a change in the status of a tape drive.
The current physical drive status is indicated in the cpqTapePhyDrvStatus variable.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqTapePhyDrvCntlrIndex
cpqTapePhyDrvBusIndex
cpqTapePhyDrvScsiIdIndex
cpqTapePhyDrvLunIndex
cpqTapePhyDrvName
cpqTapePhyDrvFwRev
cpqTapePhyDrvSerialNumber
cpqTapePhyDrvStatus
Supporting SNMP Trap Description: “Status is now [cpqTapePhyDrvStatus].”
NT Event ID: 1193 (Hex)0x843504a9 (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: External Tape Drive Status Change.
Log Message: The tape drive at location “%4”, has a new status of %7.
SNMP Trap: cpqExtTapeDriveStatusChange - 16023 in CPQFCA.MIB