HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

Microsoft Windows Event ID and SNMP traps 309
Log Severity: Warning (2)
Event Title: External Tape Drive Replace Cleaning Tape.
Log Message: The cleaning tape in the tape drive at location “%4” needs to be replaced.
SNMP Trap: cpqExtTapeDriveCleanTapeReplace - 16025 in CPQFCA.MIB
Symptom: External Tape Drive Cleaning Tape Needs Replacing. The agent has detected that an autoloader
tape unit has a cleaning tape that has been fully used and therefore needs to be replaced with a new
cleaning tape.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqFcTapeDriveCntlrIndex
cpqFcTapeDriveScsiBus
cpqFcTapeDriveScsiTarget
cpqFcTapeDriveScsiLun
cpqFcTapeDriveModel
cpqFcTapeDriveFWRev
cpqFcTapeDriveSerialNumber
cpqFcTapeDriveLocation
Supporting SNMP Trap Description: “Cleaning tape needs replacing.”
NT Event ID: 1196 (Hex)0x843504ac (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Storage System Recovery Server Option Status Change.
Log Message: Storage system “%4” has a new RSO status of %5.
SNMP Trap: cpqSsExRecoveryServerStatusChange - 8025 in CPQSTSYS.MIB
Symptom: Storage System Recovery Server Option Status Change. The agent has detected a change in the
recovery server option status of a storage system. The variable cpqSsChassisRsoStatus indicates the current
status.
User Action: If the RSO status is noSecondary(6) or linkDown(7), Be sure that the secondary server is
operational and that all cables are connected properly. If the RSO status is secondaryRunningAuto(8) or
secondaryRunningUser(9), examine the primary server for failed components.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqSsChassisName
cpqSsChassisTime
cpqSsChassisRsoStatus
cpqSsChassisIndex