HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages
Microsoft Windows Event ID and SNMP traps 327
• cpqSasPhyDrvLocationString
• cpqSasPhyDrvHbaIndex
• cpqSasPhyDrvIndex
• cpqSasPhyDrvType
• cpqSasPhyDrvModel
• cpqSasPhyDrvFWRev
• cpqSasPhyDrvSerialNumber
• cpqSasPhyDrvSasAddress
Supporting SNMP Trap Description: "Solid State Disk Wear Status is now %d."
NT Event ID: 1227 (Hex)0x843504cb (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: Drive Array Physical Drive SSD Wear Status Change.
Log Message: The physical drive in %4, %5 with serial number "%6", has a new solid state wear status of
%7. (Drive status values: 1=other, 2=ok, 3=fiftySixDayThreshold, 4=fivePercentThreshold,
5=twoPercentThreshold, 6=ssdWearOut)
SNMP Trap: cpqDaPhyDrvSSDWearStatusChange- 3049 in CPQIDA.MIB
Symptom: This trap signifies that the agent has detected a change in the SSD wear status of a drive array
physical drive. The variable cpqDaPhyDrvSSDWearStatus indicates the current SSD wear status.
User Action: If the SSD wear status is ssdWearOut(6), replace the drive.
Supporting SNMP Trap Data:
• sysName
• cpqHoTrapFlags
• cpqDaCntlrHwLocation
• cpqDaPhyDrvCntlrIndex
• cpqDaPhyDrvIndex
• cpqDaPhyDrvLocationString
• cpqDaPhyDrvType
• cpqDaPhyDrvModel
• cpqDaPhyDrvFWRev
• cpqDaPhyDrvSerialNum
• cpqDaPhyDrvSSDWearStatus
• cpqSasPhyDrvSSDWearStatus
Supporting SNMP Trap Description: "Solid State Disk Wear Status is now %d."
NT Event ID: 1228 (Hex)0x843504cc (cpqstmsg.dll)
Log Severity: Warning (2)
Event Title: IDE Disk SSD Wear Status Change.