HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

Microsoft Windows Event ID and SNMP traps 337
User Action: Replace the faulty memory.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
Supporting SNMP Trap Description: “The Advanced Memory Protection subsystem has engaged the online
spare memory.”
NT Event ID: 1027 (Hex)0x84350403 (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: The Advanced Memory Protection sub-system has detected a memory fault. Advanced ECC
has been activated. Schedule server down time to replace the memory.
SNMP Trap: cpqHeResilientAdvancedECCMemoryEngaged - 6052 in CPQHLTH.MIB
Symptom: Advanced Memory Protection Advanced ECC Memory Engaged. The Advanced Memory
Protection subsystem has detected a memory fault. Advanced ECC has been activated.
User Action: Replace the faulty memory.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
Supporting SNMP Trap Description: “The Advanced Memory Protection subsystem has engaged the
advanced ECC memory.”
NT Event ID: 1028 (Hex)0x84350404 (cpqsvmsg.dll)
Log Severity: Warning (2)
Log Message: The Advanced Memory Protection sub-system has detected a memory fault. The XOR recovery
engine has been activated. Schedule server down time to replace the memory.
SNMP Trap: cpqHeResilientMemXorMemoryEngaged - 6053 in CPQHLTH.MIB
Symptom: Advanced Memory Protection XOR Engine Memory Engaged. The Advanced Memory Protection
subsystem has detected a memory fault. The XOR engine has been activated.
User Action: Replace the faulty memory.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
Supporting SNMP Trap Description: “The Advanced Memory Protection subsystem has engaged the XOR
memory.”
NT Event ID: 1029 (Hex)0x44350405 (cpqsvmsg.dll)
Log Severity: Information (1)
Log Message: The Fault Tolerant Power Supply Sub-system has returned to a redundant state.
SNMP Trap: cpqHe3FltTolPowerRedundancyRestored - 6054 in CPQHLTH.MIB
Symptom: The Fault Tolerant Power Supplies have returned to a redundant state for the specified chassis.