HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

Microsoft Windows Event ID and SNMP traps 359
cpqRackUid
cpqRackCommonEnclosureName
cpqRackCommonEnclosureModel
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosureSparePartNumber
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “The enclosure [cpqRackCommonEnclosureName] has been removed
from rack [cpqRackName].”
NT Event ID: 1146 (Hex)0x4435047a (cpqsvmsg.dll)
Log Severity: Information (1)
Event Title: Enclosure Inserted
Log Message: This trap indicates that an enclosure has been inserted into the rack.
SNMP Trap: cpqRackEnclosureInserted - 22004 in CPQRACK.MIB
Symptom: The enclosure has been inserted. This trap indicates that an enclosure has been inserted into the
rack.
User Action: None.
Supporting SNMP Trap Data:
sysName
cpqHoTrapFlags
cpqRackName
cpqRackUid
cpqRackCommonEnclosureName
cpqRackCommonEnclosureModel
cpqRackCommonEnclosureSerialNum
cpqRackCommonEnclosureSparePartNumber
cpqRackCommonEnclosureTrapSequenceNum
Supporting SNMP Trap Description: “The enclosure [cpqRackCommonEnclosureName] has been inserted
into rack [cpqRackName].”
NT Event ID: 1147 (Hex)0xc435047b (cpqsvmsg.dll)
Log Severity: Error (3)
Event Title: Rack Enclosure Overheated
Log Message: This trap indicates that an enclosure temperature sensor has been tripped indicating an
overheat condition.
SNMP Trap: cpqRackEnclosureTempFailed - 22005 in CPQRACK.MIB
Symptom: The enclosure temperature status has been set to failed. This trap indicates that an enclosure
temperature sensor has been tripped, indicating an overheat condition.