HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

HP ProLiant server errors 37
If this message is observed without any drive movement, check if the cache module has failed and
replace it if required. If the problem persists, contact HP support ("HP contact information" on page
393).
Redundancy State: This controller has been setup to be part of a redundant pair of
controllers....
...but redundancy is temporarily disabled. Redundancy is temporarily disabled because capacity expansion,
extension, or migration is in progress. Redundancy will be enabled when this process is complete.
Action: No action is required.
Redundancy State: This controller has been setup to be part of a redundant pair of
controllers....
...but redundancy is disabled. Redundancy is disabled for an unknown reason.
Action: Contact HP support ("HP contact information" on page 393).
Redundant Path Failure: Multi-domain path failure
Action: Check the storage device I/O module and cables to restore redundant paths.
Redundant Path Failure: The logical drive is degraded due to the loss of a redundant
path.
Action: Check the storage box I/O module and cables to restore redundant paths to the logical drive.
Redundant Path Failure: The physical drive is degraded due to the loss of a redundant
path.
Action: Check the storage box I/O module and cables to restore redundant paths to the physical drive.
Redundant Path Failure: Warning: Redundant I/0 modules of this storage box...
...are not cabled in a recommended configuration.
Action: To correctly connect the cables to the storage system, see the product user guide.
Smart SSD State: SSD has less than 2% of usage remaining before wearout.
Action: Monitor the drive frequently and replace the drive before wearout.
Smart SSD State: SSD has less than 2% of usage remaining before wearout…
…It has less than an estimated 56 days before it reaches the maximum usage limit and should be replaced as soon as
possible.
Action: Replace the SSD as soon as possible.
Smart SSD State: SSD has less than 5% of usage remaining before wearout.
Action: Monitor the drive frequently and replace the drive before wearout.