HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

HP ProLiant server errors 38
Smart SSD State: SSD has less than 5% of usage remaining before wearout…
…It has less than an estimated 56 days before it reaches the maximum usage limit and should be replaced as soon as
possible.
Action: Replace the SSD as soon as possible.
Smart SSD State: SSD has less than an estimated 56 days before it reaches the
maximum usage limit for writes (wearout)...
...and should be replaced as soon as possible.
Action: Replace the SSD as soon as possible.
Smart SSD State: SSD has reached the maximum rated usage limit for writes
(wearout) and should be replaced immediately.
Action: Replace the SSD immediately.
Smart SSD State: The SmartSSD Wear Gauge log is full…
...Wear Gauge parameters are not available.
Action: SSD wearout cannot be monitored. If wearout needs to be monitored, replace the drive.
Storage Enclosure: The enclosure is reporting a critical temperature status
condition...
...Power off the enclosure immediately.
Action: Power off the enclosure immediately. Be sure that all the fans are connected and operating properly.
Replace any defective fans. For better airflow remove any dust buildup from fans or other areas. If the
problem persists, contact HP support ("HP contact information" on page 393).
Storage Enclosure: One or more fans have failed.
Action: Replace the failed fan.
Storage Enclosure: Warning: The enclosure is reporting a high temperature status.
Action: Be sure that all fans are connected and operating properly. Replace any defective fans. For better
airflow, remove any dust buildup from fans or other areas. If the problem persists, contact HP support ("HP
contact information" on page 393).
Storage Enclosure: Warning: One or more redundant power supplies in this
enclosure has failed or is not plugged in correctly.
Action: Reseat the power supply firmly and check the power cable. If the problem persists, check the power
supply.