HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

HP ProLiant server errors 51
Action: Run Insight Diagnostics and replace failed components as indicated.
162-System Options Not Set
Audible Beeps: 2 long
Possible Cause: Configuration is incorrect. The system configuration has changed since the last boot
(addition of a hard drive, for example) or a loss of power to the real-time clock has occurred. The real-time
clock loses power if the onboard battery is not functioning correctly.
Action: Press the F1 key to record the new configuration. Run the server setup utility to change the
configuration. If this message persists, you may need to replace the onboard battery.
163-Time & Date Not Set
Audible Beeps: 2 long
Possible Cause: Invalid time or date in configuration memory.
Action: Run the server setup utility and correct the time or date.
172-1-Configuration Non-volatile Memory Invalid
Audible Beeps: None
Possible Cause: Nonvolatile configuration corrupted.
Action: Run the server setup utility and correct the configuration.
180-Log Reinitialized
Audible Beeps: None
Possible Cause: The IML has been reinitialized due to corruption of the log.
Action: Event message, no action is required.
200 Series
201-Memory Error
Audible Beeps: None
Possible Cause: Memory failure detected.
Action: Run Insight Diagnostics and replace failed components as indicated.
203-Memory Address Error
Audible Beeps: None
Possible Cause: Memory failure detected.
Action: Run Insight Diagnostics and replace failed components as indicated.