HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

HP ProLiant server errors 55
210-Memory Board Power Fault on board X
Audible Beeps: 1 long, 1 short
Possible Cause: A problem exists with a memory board powering up properly.
Action: Exchange DIMMs and retest. Replace the memory board if problem persists.
210-Memory Board Failure on board X
Audible Beeps: 1 long, 1 short
Possible Cause: A problem exists with a memory board powering up properly.
Action: Exchange DIMMs and retest. Replace the memory board if problem persists.
212-Processor Cache Size Mismatch Detected - System Performance may be Erratic!
Audible beeps: 1 long, 1 short
Possible cause: Two processors with different cache sizes are installed.
Action: Remove one of the processors.
212-Processor Failed, Processor X
Audible Beeps: 1 short
Possible Cause: Processor in slot X failed.
Action:
1. Run Insight Diagnostics.
CAUTION: Before removing or replacing any processors, be sure to follow the guidelines
provided in "Performing processor procedures in the troubleshooting process." Failure to follow
the recommended guidelines can cause damage to the system board, requiring replacement of
the system board.
2. Replace failed components as indicated.
228 - DIMM Configuration Error - Processor X, Channel Y
- Memory channel not populated in correct order. See User Guide
- System Halted!
Audible beeps: Repeating long beep
Possible cause: The memory channel is not populated in the correct order.
Action: See the server user guide for corrective action.
229 - DIMM Configuration Error - Processor X, DIMM Y
- Unsupported DIMM. - System Halted!
Audible beeps: Repeating long beep
Possible cause: An unknown DIMM type was detected.
Action: Install the correct DIMM type.