HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

HP ProLiant server errors 67
1700 Series
1700-Slot X Drive Array - Please replace Cache Module Battery Pack...
...Caching will be enabled once the Battery Pack has been replaced and charged.
Audible Beeps: None
Possible Cause: The battery needs to be replaced and charged.
Action: Replace and charge the battery pack.
1700-Slot X Drive Array - Please replace Array Accelerator Battery...
...The Array Accelerator Cache will be enabled once the battery has been replaced and charged.
Audible Beeps: None
Possible Cause: The battery needs to be replaced and charged.
Action: Replace and charge the Array Accelerator battery.
1701-Slot X Drive Array - Please install Cache Module Battery Pack...
...Caching will be enabled once the Battery Pack is installed and charged.
Audible Beeps: None
Possible Cause: The battery needs to be installed and charged.
Action: Install and charge the battery pack.
1701-Slot X Drive Array - Please install Array Accelerator Battery...
...The Array Accelerator Cache will be enabled once the battery is installed and charged.
Audible Beeps: None
Possible Cause: The battery needs to be installed and charged.
Action: Install and charge the Array Accelerator battery.
1703 - Slot X Drive Array controller - Memory Self-Test Error - Access to all storage
has been disabled...
...Upgrade to the latest firmware. If the problem persists, replace the Cache Module or Controller.
Audible Beeps: None
Possible Cause: The cache module or controller has failed or is experiencing a fault.
Action:
Upgrade to the latest firmware.
If this error persists, replace the cache module or controller.
1703 - Slot X Drive Array controller - Memory Self-Test Error - Access to all storage
has been disabled...
...Access to all storage has been disabled. Replace the Array Accelerator daughtercard if this error persists after
restarting system.