HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

HP ProLiant server errors 68
Audible Beeps: None
Possible Cause: The cache module has failed or is experiencing a fault.
Action: Replace the cache module.
1704-Unsupported Virtual Mode Disk Operation - System Halted
Audible Beeps: None
Possible Cause: The operating system currently running does not support virtual DMA service.
Action: Load or update the device driver appropriate for the operating system.
1705-Slot X Drive Array - Please replace Cache Module Super-Cap...
...Caching will be enabled once the Super-Cap has been replaced and charged.
Audible beeps: None
Possible cause: The Super-Cap failed to charge.
Action: Replace the Cache Module Super-Cap.
1705-Slot X Drive Array - Please replace Array Accelerator Super-Cap...
...The Array Accelerator Cache will be enabled once Super-Cap has been replaced and charged.
Audible beeps: None
Possible cause: The Super-Cap failed to charge.
Action: Replace the Array Accelerator Super-Cap.
1706-The Extended BIOS Data Area in Server Memory has been Overwritten...
...Smart Array Interrupt 13h BIOS Cannot Continue - System Halted
Audible Beeps: None
Possible Cause: An application has overwritten memory reserved by the Smart Array controller.
Action: If this occurs when a particular application is loaded, check for an updated version of that
application.
1706-Smart Array Controller Extended BIOS Data Area Memory Corrupted.
...Int 13h BIOS Cannot Continue - System Halted.
Audible Beeps: None
Possible Cause: An application has overwritten memory reserved by the Smart Array controller.
Action: If this occurs when a particular application is loaded, check for an updated version of that
application.
1707-Slot X Drive Array Controller - Bootstrap NVRAM checksum failed
The second line of the message includes one of the following lines of text:
(unrecoverable error)
or