HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

HP ProLiant server errors 80
1764-Slot X Drive Array - Capacity Expansion Process is Temporarily Disabled...
(followed by one of the following:)
...Expansion will resume when Array Accelerator has been reattached.
* Expansion will resume when Array Accelerator has been replaced.
* Expansion will resume when Array Accelerator RAM allocation is successful.
* Expansion will resume when Array Accelerator battery/capacitor reaches full charge.
* Expansion will resume when Automatic Data Recovery has been Completed.
* Expansion will resume when Array Accelerator battery/capacitor is connected.
Audible Beeps: None
Possible Cause: The capacity expansion process has been temporarily disabled.
Action: Follow the action that is displayed onscreen to resume the capacity expansion process.
1768-Slot X Drive Array - Resuming Logical Drive Expansion Process
Audible Beeps: None
Possible Cause: Power was lost while a logical expansion operation was performed. A controller reset or
power cycle occurs while array expansion is in progress.
Action: No action is required.
1769-Slot X Drive Array - Drive(s) Disabled due to Failure During Expansion...
(possibly followed by one of the following additional details:)
...* Cache Module Removed or Failed; Expansion Progress Data Lost.
* Expansion Progress Data Could Not Be Read From Cache Module.
* Expansion Aborted due to Unrecoverable Drive Errors.
* Expansion Aborted due to Cache Module Errors.
Select "F1" to continue with logical drives disabled
Select "F2" to accept data loss and to re-enable logical drives
Audible Beeps: None
Possible Cause: Data was lost while the array was expanded; therefore, the drives have been temporarily
disabled. Capacity expansion failed due to:
Cache module or hard drive failed or was removed; expansion progress data lost
Expansion progress data could not be read from cache module
Expansion aborted due to unrecoverable drive errors
Expansion aborted due to cache module errors
Action:
Press the F1 key to continue with the logical drives disabled. Or, press the F2 key to accept the data loss
and re-enable the logical drives.
Restore data from backup.
Replace drive or cache module, as appropriate.
1769-Slot X Drive Array - Drive(s) Disabled due to Failure During Expansion...
(possibly followed by one of the following additional details:)
...* Array Accelerator Removed or Failed; Expansion Progress Data Lost.