HP ProLiant Gen8 Troubleshooting Guide Volume II: Error Messages

HP ProLiant server errors 93
Audible Beeps: None
Possible Cause: The Cache Module has a critical error.
Action: Replace the Cache Module.
1805-Slot X Drive Array - Cache Module Super-Cap is not installed...
IMPORTANT: Unsupported Configuration: Cache Module functionality is limited.
Action: Install the Super-Cap to remove these limitations.
Audible Beeps: None
Possible Cause: The Cache Module Super-Cap is not installed.
Action: Install the Super-Cap.
1806-Slot X Drive Array - Cache Module flash memory is not installed;...
IMPORTANT: Unsupported Configuration: Cache Module functionality is limited.
Action: Install the flash memory to remove these limitations.
Audible Beeps: None
Possible Cause: The Cache Module flash memory is not installed.
Action: Install the flash memory.
1807-Slot X Drive Array - Cache Module incompatible with this controller.
IMPORTANT: Access to all storage has been disabled.
Action: Replace the Cache Module to re-enable all storage.
Audible Beeps: None
Possible Cause: The Cache Module is incompatible with the controller.
Action: Replace the Cache Module.
1808-Slot X Drive Array - Cache Module critical error
IMPORTANT: Access to all storage has been disabled.
Action: Replace the Cache Module to re-enable all storage.
Audible Beeps: None
Possible Cause: The Cache Module has a critical error.
Action: Replace the Cache Module.
Event list error messages
Introduction to event list error messages
This section contains event list error messages recorded in the IML, which can be viewed through different
tools.
The format of the list is different when viewed through different tools. An example of the format of an event
as displayed on the IMD follows: