HP ProLiant ML350p Gen8 Server User Guide

Operations 29
a.
Place the server on a flat, level surface with the access panel facing up.
b. Remove the access panel (on page 23).
5. For rack models, do the following:
a. Extend the server from the rack (on page 24).
b. Remove the access panel (on page 23).
c. Release thumbscrews and remove the rack bezel.
6. Remove the fan cage.
7. Disconnect and remove the optical drive power and data cables.
8. Remove the optical drive.
Remove the component drive cage blank
1. Do one of the following:
o For tower models, open and remove the bezel ("Remove the tower bezel" on page 21).
o For rack models, do the following:
a. If installed, remove the security bezel (on page 21).
b. Remove the access panel. ("Remove the access panel" on page 23)
c. Release thumbscrews and remove the rack bezel.
2. Remove the component drive cage blank.
WARNING:
To reduce the risk of personal injury from an electrical hazard, do not remove more
than one drive cage at a time.