HP ProLiant ML350p Gen8 Server User Guide

Hardware options installation 47
o
Cable routing to box 3
11. Install the fan cage.
12. Install the air baffle (on page 26).
13. For tower models, do the following:
a. Install the access panel (on page 24).
b. Return the server to an upright position.
14. For rack models, do the following:
a. Install the access panel (on page 24).
b. Slide the server into the rack.
15. Connect each power cord to the server.
16. Connect each power cord to the power source.
17. Press the Power On/Standby button.
The server exits standby mode and applies full power to the system. The system power LED changes
from amber to green.
18. Do one of the following:
o For tower models, install the bezel.
o For rack models, if removed, install the security bezel (on page 21).
Second processor option
The server supports single-processor and dual-processor operation.
When processor 2 is installed, fan 1 must also be installed.
CAUTION: To avoid damage to the processor and system board, only authorized personnel
should attempt to replace or install the processor in this server.
CAUTION: To prevent possible server malfunction and damage to the equipment, multiprocessor
configurations must contain processors with the same part number.