Compaq ProLiant ML370 G2 Service Update

Compaq ProLiant ML370 G2 Service Update 11
Rev. 1.0 Page 11 of 18
Tower Server
Step Action
1.
Back up your server data.
2.
Shut down the operating system as directed in your operating system instructions.
3.
Open the front bezel.
4.
Press the Power On/Standby button. The system power LED turns amber when the server
is powered off in this manner.
WARNING: Setting the server Power On/Standby button to the off position removes power from
most areas of the server; this process may take 30 seconds. Portions of the power supply and
some internal circuitry remain active until the AC power cord is disconnected.
If the server has multiple power supplies installed, it is necessary to remove all power cords to
remove all power from the system.
5.
Disconnect all AC power cords from the AC outlets, then from the server.
6.
Disconnect all external peripheral devices from the server.
7.
Place the server on a sturdy, level surface.