ProLiant ML530 Servers Maintenance and Service Guide

Table Of Contents
Diagnostics and Troubleshooting 3-41
Table 3-20
ADU Diagnostic Messages
continued
Message Description Recommended Action
Accelerator
status: Valid data
found at reset
Valid data was found in posted write
memory at reinitialization. Data will
be flushed to disk.
Not an error or data loss condition. No action
required.
Accelerator
status: Warranty
alert
Catastrophic problem with array
accelerator board. Refer to the other
messages on Diagnostics screen for
exact meaning of this message.
Replace the array accelerator board.
Adapter/NVRAM
ID mismatch
EISA nonvolatile RAM has an ID for a
different controller from the one
physically present in the slot.
Run the System Configuration Utility.
Array accelerator
battery pack X
not fully charged
Battery is not fully charged. If 75% of batteries present are fully charged,
array accelerator is fully operational. If less than
75% of batteries are fully charged, allow
36 hours to recharge them.
Array accelerator
battery pack X
below reference
voltage
(recharging)
Battery pack on array accelerator is
below required voltage levels.
Allow enough time for batteries to recharge
(36 hours). If batteries have not recharged after
36 hours, replace the array accelerator board.
Board in use by
expand operation
Array accelerator memory is in use
by Expand operation.
Operate system without array accelerator board
until Expand operation completes.
Board not
attached
Array controller configured for use
with array accelerator board, but one
is not attached.
Attach array accelerator board to array
controller.
Configuration
signature is zero
ADU detected that nonvolatile RAM
contains a configuration signature of
zero. Old versions of the System
Configuration Utility could cause this.
Run the latest version of System Configuration
Utility to configure the controller and nonvolatile
RAM.
Configuration
signature
mismatch
Array accelerator board configured
for a different array controller board.
Configuration signature on array
accelerator board does not match the
one stored on the array controller
board.
To recognize the array accelerator board, run
the Array Configuration Utility.
Controller
communication
failure occurred
Controller communication failure
occurred.
ADU was unable to successfully issue
commands to the controller in this slot.
Controller
detected.
NVRAM
configuration not
present
EISA nonvolatile RAM does not
contain a configuration for this
controller.
Run the System Configuration Utility to
configure the nonvolatile RAM.
Controller
firmware needs
upgrading
Controller firmware is below the
latest recommended version.
Run Options ROMPaq to upgrade the controller
to the latest firmware revision.
continued