3-42 Compaq ProLiant ML530 Servers Maintenance and Service Guide
Table 3-20
ADU Diagnostic Messages
continued
Message Description Recommended Action
Controller is
located in
special video
slot
Controller is installed in slot for
special video control signals. If
controller is used in this slot, LED
indicators on front panel may not
function properly.
Install the controller in a different slot and run
the System Configuration Utility to configure the
controller and nonvolatile RAM. Then run the
Array Configuration Utility to configure the
controller.
Controller is not
configured
Controller is not configured. If
controller was previously configured
and drive locations were changed,
there may be a problem with
placement of the drives. ADU
examines each physical drive and
looks for drives that have been
moved to a different drive bay.
Look for messages indicating which drives have
been moved. If none appear and drive swapping
did not occur, run the Array Configuration Utility
to configure the controller and run the System
Configuration Utility to configure nonvolatile
RAM. Do not run either utility if you believe
drive swapping has occurred.
Controller
reported POST
error.
Error Code: X
The controller returned an error from
its internal Power-On Self-Test.
Replace the controller.
Controller
restarted with a
signature of zero
ADU did not find a valid configuration
signature to use to get the data.
Nonvolatile RAM may not be present
(unconfigured) or the signature
present in nonvolatile RAM may not
match the signature on the
controller.
Run the System Configuration Utility to
configure the controller and nonvolatile RAM.
Disable
command issued
Posted-writes have been disabled by
the Accelerator Disable command.
This occurred because of an
operating system device driver.
Restart the system. Run the Array Configuration
Utility to reinitialize the array accelerator board.
Drive (bay) X
firmware needs
upgrading
Firmware on this physical drive is not
the latest recommended version.
Run the Options ROMPaq Utility to upgrade the
drive firmware to the latest revision.
Drive (bay) X has
insufficient
capacity for its
configuration
Drive has insufficient capacity to be
used in this logical drive
configuration.
Replace this drive with a larger capacity drive.
Drive (bay) X has
invalid M&P
stamp
Physical drive has invalid monitor
and performance data.
Run the System Configuration Utility to properly
initialize this drive.
Drive (bay) X has
loose cable
The array controller could not
communicate with this drive at
power-up. This drive has not
previously failed.
Check all cable connections first. The cables
could be bad, loose, or disconnected. Turn on
the system and attempt to reconnect
signal/power cable to the drive. If this does not
work, replace the cable. If that does not work,
the drive may need to be replaced.
Drive (bay) X is a
replacement
drive
This drive has been replaced. This
message displays if a drive is
replaced in a fault tolerant logical
volume.
If the replacement was intentional, allow the
drive to rebuild.
continued