ProLiant ML530 Servers Maintenance and Service Guide
Table Of Contents
- Compaq ProLiant ML530 Servers Maintenance and Service Guide
- Notice Page
- Table of Contents
- About This Guide
- Chapter 1: Illustrated Parts List
- Chapter 2: Removal and Replacement Procedures
- Electrostatic Discharge Information
- Symbols on Equipment
- Preparation Procedures
- Tower Model Front Bezel Door
- RackMount Bezel
- Access Panel
- Fans
- Removable Media and Mass Storage Devices
- Cable Routing Diagrams
- System Board Tray
- System Board Components
- HotPlug Power Supplies
- Power Backplane Board
- Power On/Standby Switch
- Chapter 3: Diagnostics and Troubleshooting
- Diagnostic Tools Utility Overview
- Default Configuration
- Utilities Access
- PowerOn SelfTest
- Diagnostics Software
- Steps for Diagnostics
- 100–199, Primary Processor Test Error Codes
- 200–299, Memory Test Error Codes
- 300–399, Keyboard Test Error Codes
- 400–499, Parallel Printer Test Error Codes
- 500–599, Video Display Unit Test Error Codes
- 600–699, Diskette Drive Test Error Codes
- 800–899, Video Board Test Error Codes
- 1100–1199, Serial Test Error Codes
- 1200–1299, Modem Communications Test Error Codes
- 1700–1799, Hard Drive Test Error Codes
- 1900–1999, Tape Drive Test Error Codes
- 2400–2499, Advanced VGA Board Test Error Codes
- 6000–6099, Compaq NIC Boards Test Error Codes
- 6500–6599, SCSI Hard Drive Test Error Codes
- 6700–6799, SCSI Tape Drive Test Error Codes
- 8600–8699, Pointing Device Interface Test Error Codes
- Array Diagnostic Utility
- Integrated Management Log
- Rapid Error Recovery
- Remote Service Features
- ROMPaq Error Recovery Options
- Compaq Insight Manager
- Chapter 4: Connectors, Switches, Jumpers, and LED Indicators
- Chapter 5: Physical and Operating Specifications
- Index

3-44 Compaq ProLiant ML530 Servers Maintenance and Service Guide
Table 3-20
ADU Diagnostic Messages
continued
Message Description Recommended Action
Error occurred
reading RIS copy
from SCSI Port X
Drive ID X
An error occurred while ADU was
trying to read the RIS from this drive.
If there were multiple errors, this drive may
need to be replaced.
FYI: Drive (bay) X
is third-party
supplied
The installed drive was not supplied
by Compaq.
If problems exist with this drive, replace it with
a Compaq drive.
Identify
controller data
did not match
with NVRAM
The identify controller data from the
array controller did not match the
information stored in nonvolatile
RAM. This could occur if new,
previously configured drives have
been placed in a system that has
also been previously configured. It
could also occur if the firmware on
the controller has been upgraded and
the System Configuration Utility was
not run.
Check the identify controller data under the
Inspect Utility. If the firmware version field is the
only difference between the controller and
nonvolatile RAM data, this is not a problem.
Otherwise, run the System Configuration Utility.
Identify logical
drive data did
not match with
NVRAM
The identify unit data from the array
controller did not match with the
information stored in nonvolatile
RAM. This could occur if new,
previously configured drives have
been placed in a system that has
also been previously configured.
Run the System Configuration Utility to
configure the controller and nonvolatile RAM.
Insufficient
adapter
resources
The adapter does not have sufficient
resources to perform operations to
the array accelerator board. Drive
rebuild may be occurring.
Operate the system without the array
accelerator board until the drive rebuild
completes.
Inter-controller
link connection
could not be
established
Unable to communicate over the link
connecting the redundant controllers.
Make sure both controllers are using the same
hardware and firmware revisions. If one
controller is failed, replace it.
Less than 75%
batteries at
sufficient voltage
Operation of array accelerator board
has been disabled due to less than
75% of battery packs being at
sufficient voltage level.
Allow sufficient time for batteries to recharge
(36 hours). If batteries have not recharged after
36 hours, replace the array accelerator board.
Less than 75%
batteries at
sufficient
voltage. Battery
pack X below
reference
voltage.
Battery pack on array accelerator is
below required voltage levels.
Allow sufficient time for batteries to recharge
(36 hours). If batteries have not recharged after
36 hours, replace the array accelerator board.
Logical drive X
failed due to
cache error
This logical drive failed due to a
catastrophic cache error.
Replace the array accelerator board and
reconfigure using the Array Configuration Utility.
continued