ProLiant ML530 Servers Maintenance and Service Guide
Table Of Contents
- Compaq ProLiant ML530 Servers Maintenance and Service Guide
- Notice Page
- Table of Contents
- About This Guide
- Chapter 1: Illustrated Parts List
- Chapter 2: Removal and Replacement Procedures
- Electrostatic Discharge Information
- Symbols on Equipment
- Preparation Procedures
- Tower Model Front Bezel Door
- RackMount Bezel
- Access Panel
- Fans
- Removable Media and Mass Storage Devices
- Cable Routing Diagrams
- System Board Tray
- System Board Components
- HotPlug Power Supplies
- Power Backplane Board
- Power On/Standby Switch
- Chapter 3: Diagnostics and Troubleshooting
- Diagnostic Tools Utility Overview
- Default Configuration
- Utilities Access
- PowerOn SelfTest
- Diagnostics Software
- Steps for Diagnostics
- 100–199, Primary Processor Test Error Codes
- 200–299, Memory Test Error Codes
- 300–399, Keyboard Test Error Codes
- 400–499, Parallel Printer Test Error Codes
- 500–599, Video Display Unit Test Error Codes
- 600–699, Diskette Drive Test Error Codes
- 800–899, Video Board Test Error Codes
- 1100–1199, Serial Test Error Codes
- 1200–1299, Modem Communications Test Error Codes
- 1700–1799, Hard Drive Test Error Codes
- 1900–1999, Tape Drive Test Error Codes
- 2400–2499, Advanced VGA Board Test Error Codes
- 6000–6099, Compaq NIC Boards Test Error Codes
- 6500–6599, SCSI Hard Drive Test Error Codes
- 6700–6799, SCSI Tape Drive Test Error Codes
- 8600–8699, Pointing Device Interface Test Error Codes
- Array Diagnostic Utility
- Integrated Management Log
- Rapid Error Recovery
- Remote Service Features
- ROMPaq Error Recovery Options
- Compaq Insight Manager
- Chapter 4: Connectors, Switches, Jumpers, and LED Indicators
- Chapter 5: Physical and Operating Specifications
- Index

3-50 Compaq ProLiant ML530 Servers Maintenance and Service Guide
Table 3-20
ADU Diagnostic Messages
continued
Message Description Recommended Action
Warning bit
detected
A monitor and performance threshold
violation may have occurred. Status
of a logical drive may not be OK.
Check the other error messages on the
diagnosis screen for an indication of the
problem.
Write memory
error
Data could not be written to cache
memory. This typically means that a
parity error was detected while
writing data to cache. This could be
caused by incomplete connection
between cache and controller. This is
not a data loss circumstance.
With power to system turned off, verify that the
cache board is fully connected to controller.
Wrong
accelerator
This could mean that either the board
was replaced in the wrong slot or
placed in a system that was
previously configured with another
board type. Included with this
message is a message indicating the
type of adapter sensed by ADU and a
message indicating the type of
adapter last configured in EISA
nonvolatile RAM.
Check the diagnosis screen for other error
messages. Run the System Configuration Utility
to update the system configuration.