ProLiant ML530 Servers Maintenance and Service Guide
Table Of Contents
- Compaq ProLiant ML530 Servers Maintenance and Service Guide
- Notice Page
- Table of Contents
- About This Guide
- Chapter 1: Illustrated Parts List
- Chapter 2: Removal and Replacement Procedures
- Electrostatic Discharge Information
- Symbols on Equipment
- Preparation Procedures
- Tower Model Front Bezel Door
- RackMount Bezel
- Access Panel
- Fans
- Removable Media and Mass Storage Devices
- Cable Routing Diagrams
- System Board Tray
- System Board Components
- HotPlug Power Supplies
- Power Backplane Board
- Power On/Standby Switch
- Chapter 3: Diagnostics and Troubleshooting
- Diagnostic Tools Utility Overview
- Default Configuration
- Utilities Access
- PowerOn SelfTest
- Diagnostics Software
- Steps for Diagnostics
- 100–199, Primary Processor Test Error Codes
- 200–299, Memory Test Error Codes
- 300–399, Keyboard Test Error Codes
- 400–499, Parallel Printer Test Error Codes
- 500–599, Video Display Unit Test Error Codes
- 600–699, Diskette Drive Test Error Codes
- 800–899, Video Board Test Error Codes
- 1100–1199, Serial Test Error Codes
- 1200–1299, Modem Communications Test Error Codes
- 1700–1799, Hard Drive Test Error Codes
- 1900–1999, Tape Drive Test Error Codes
- 2400–2499, Advanced VGA Board Test Error Codes
- 6000–6099, Compaq NIC Boards Test Error Codes
- 6500–6599, SCSI Hard Drive Test Error Codes
- 6700–6799, SCSI Tape Drive Test Error Codes
- 8600–8699, Pointing Device Interface Test Error Codes
- Array Diagnostic Utility
- Integrated Management Log
- Rapid Error Recovery
- Remote Service Features
- ROMPaq Error Recovery Options
- Compaq Insight Manager
- Chapter 4: Connectors, Switches, Jumpers, and LED Indicators
- Chapter 5: Physical and Operating Specifications
- Index

Diagnostics and Troubleshooting 3-53
Event Messages
Table 3-21
Event Messages
Event Type Event Message Action
Machine Environment
Fan Failure System Fan Failure (Fan X, Location). Replace fan.
Fan Inserted System Fan Inserted (Fan X, Location). None
Fan Removed System Fan Removed (Fan X, Location). None
Fans Not Redundant System Fans Not Redundant. Add fan.
Overheat Condition System Overheating (Zone X, Location). Check fans.
Main Memory
Correctable Error
Threshold exceeded
Corrected Memory Error Threshold passed
(Slot X, Memory Module X).
Replace the defective memory
module.
Corrected Memory Error Threshold passed
(System Memory).
Replace the memory modules one
at a time (if more than one) and
retest the system after each
replacement.
Corrected Memory Error Threshold passed
(Memory Module unknown).
Replace the memory modules one
at a time (if more than one).
Uncorrectable Error Uncorrectable Memory Error (Slot X,
Memory Module X).
Replace the defective memory
module.
Uncorrectable Memory Error (System
Memory).
Replace the defective memory
module.
Uncorrectable Memory Error (Memory
Module unknown).
Replace the memory modules one
at a time (if more than one) and
retest the system after each
replacement.
Processor
Correctable Error
Threshold exceeded
Processor Correctable Error Threshold
passed (Slot X, Socket X).
Replace the processor.
Uncorrectable Error Unrecoverable Host Bus Data Parity Error. Replace the processor.
Host Bus Error Unrecoverable Host Bus Address Parity
Error.
Call the service provider or Compaq
for diagnosis.
PCI Bus Error PCI Bus Error (Slot X, Bus X, Device X,
Function X).
Power down PCI slot and replace
board.
continued