ProLiant ML530 Servers Maintenance and Service Guide

Table Of Contents
3-54 Compaq ProLiant ML530 Servers Maintenance and Service Guide
Table 3-21
Event Messages
continued
Event Type Event Message Action
Power Subsystem
Power Supply Failure System Power Supply Failure
(Power Supply X).
Replace power supply.
Power Supply Inserted System Power Supply Inserted
(Power Supply X).
None
Power Supply Removed System Power Supply Removed
(Power Supply X).
None
Power Supply
Not Redundant
System Power Supplies Not Redundant. Add power supply.
AC Voltage Problem System AC Power Problem
(Power Supply X).
Check the input power voltage.
Power AC Overload System AC Power Overload
(Power Supply X).
1. Change the input power to
220V.
2. Add an additional
power supply, or replace with
one able to supply present
load.
3. Reduce the load.
Automatic Server Recovery2
System Lockup ASR Lockup Detected: Cause Call the service provider or Compaq
for diagnosis.
Operating System
Blue Screen Trap: Cause [NT]
Kernel Panic: Cause [UNIX]
System Crash
Abnormal Program Termination: Cause
[NetWare]
Refer to the documentation for the
operating system.
Automatic Operating System Shutdown
Initiated Due to Fan Failure
Automatic Operating System Shutdown
Initiated Due to Overheat Condition
Automatic
OS Shutdown
Fatal Exception (Number X, Cause)
Refer to the documentation for the
operating system.